الرئيسية / الفعاليات العلمية / ابحاث / Using SSNTD Technique to Assess Radon Flux Density in Liquid Cleaning Materials Samples Available in Iraqi Pharmacies and Markets

Using SSNTD Technique to Assess Radon Flux Density in Liquid Cleaning Materials Samples Available in Iraqi Pharmacies and Markets

ples Available in Iraq
Ali Abid Abojassim1*, Hussien Abid Ali Bakir1, Mokhalad Ali Zbalh2, Ban Ali Al-Ruwaishidi1
1Department of Physics, Faculty of Science, University of Kufa, Al-Najaf, Iraq
2Genetic engineering Department, Biotechnology College, Al-Qasim Green University, Babylon, Iraq
*Corresponding Author E-mail:
[email protected]
ABSTRACT:
In this study, thirty samples of cleaning materials (liquid) were collected from the local pharmacies and markets
of Al-Najaf government to assess radium content and radon flux density (radon exhalation rate) using LR-115
Type II technique. These samples were divided into six groups according to country of origin (i.e. Iraq, Turkey,
Jordon, Saudi Arabia, Egypt and other countries). The results demonstrate that, the average of radium content in
six groups (Iraq, Turkey, Jordon, Saudi Arabia, Egypt and other counties) were 55.22±0.29 Bq/kg, 56.15±0.37
Bq/kg, 32.38±0.37 Bq/kg, 27.28±0.63 Bq/kg, 60.34±0.73 Bq/kg and 41.90±0.23 Bq/kg respectively. The average
values of radon flux density were
9.24±0.25 μBq/m2.h, 11.00±0.31 μBq/m2.h, 6.06±0.31 μBq/m2.h, 4.55±0.59
μBq/m2.h,11.17±0.64 μBq/m2.h and 7.33±0.20 μBq/m2.h respectively. All values of radium content and radon
flux density in the study samples were found to be less than the allowed the values of 57.600 mBq/m
2.h and
370 Bq/kg published by UNSCEAR and OECD.
KEYWORDS: Radium content, Radon exhalation rates, cleaning material and LR-115 Type II detector.